FEC MODES

These modes are used for broadcasting (e.g. transmission from a station tothe destination of one or several others, with protection against errors: FEC = ForwardError Correction).

AUTOSPEC

Protocol: characters are transmitted consecutively.
Code: Bauer code, 32 character set, 10 bit words (5 bits like ITA2 and 5 bitsfor the error detection and correction by a Hamming code).
Standard speeds: 62.3, 68.5, 102.6 and 137 Bauds.
Current modulation: FSK

CIS11

Protocol: characters are transmitted consecutively.
Code: 11 bit words, 32 characters set (5 bits of the Baudot code, 2synchronization bits and 4 bits for the error detection and correction by a Hamming code).
Current speeds: 75, 100 bauds.

Pocsag Decoder Android

Current modulation: FSK
Main use: aeronautical weather report from eastern Europe.

DGPS

Dgsp characteristics

Protocol: transmission of frames of codewords. The number of words in a framedepends on the message type and is variable in the same type, not exceeding 33.
The first codeword contains an 8 bits preamble, the message type (6 bits) and the stationId (10 bits).
The second codeword gives the 'Modified Z-count' (13 bits) which is the starttime of the next frame preamble, the sequence number (3 bits), the length of the frame (5bits) which is the number of codewords following this one and the station health (3 bits).
The 2 first codewords are common to all messages. The meaning of the next ones dependson the message type.
Code: 30 bit words:
Current speeds: 100, 200 bauds. Other rates are also possible but not used.
Current modulation: MSK
Main use: worldwide transmissions of corrections to improve the accuracy of datareceived from GPS devices. The transmitters are located on the costs and intended to themaritime service. They transmit in the hectometric band around 300 Khz, with a rangearound 100-200 Kms.
RadioRaft particulars:

Dgsp messages display

Refer to recommendation ITU-R M.823 to interpret the different fields. Herethey are in brief:

MSG xx Station463 Z-Time 37:4.2 Sequence:0 Length:12 Health:0

MSG: xx is the message type
Station: reference station number
Z-time
: modified Z-count, time at which the corrections are computed in unitof 0.6 sec. See the options.
Sequence: sequence number (0-7), increments on each frame
Length: frame length, number of words following this one (0-31)
Health: station health (0-7)
Data: 012345 6789AB 1A2B3C...
Station coordinates (mtrs): X=4296717.12 Y= -263398.80 Z= 4690668.64
Satellite 23 IOD:0 Datahealthy Sat S/N not tracked Sat healthy
No new IOD Loss of satellite warning in (mn): 35
For each satellite:
Satellite number
IOD: Issue Of Data
Data healthy (or unhealthy)
Sat S/N not tracked (otherwise the signal to noise ratio is given inDb(Hz))
Sat healthy (consider sat healthy even if data unhealthy)
No new IOD (or New IOD soon)
Loss of satellite... if scheduled, time remaining before loss
Position: 47°38'48.1' North 3°30'36.0'West
Range: 170 Km Frequency: 298.0 KhzR/beacon operation normal
Tx.Id: 332 100 Bauds MSK synchronous No added coding
For each beacon in the almanach:
Position: lattitude and longitude of the station
Range: beacon service range
Frequency: beacon frequency
R/beacon operation normal: health of the beacon as plain text
Tx.Id: transmit station number. Don't confuse with 'referencestation number'.
100 bauds: data rate of the beacon
MSK: the modulation the beacon is using (also FSK)
Synchronous: synchro type (also asynchronous)
No added coding: broadcast coding (also 'FEC coding')
  • Messages 16, ASCII text information follows this header.
  • Dgsp options

    Stop on error
    If an error is received in a word and this option is set, the next words are notdisplayed. RadioRaft is waiting for the next frame.
    Display hex data
    You may avoid to display hex data by disabling this option. Only the 2 first words in aframe are displayed.
    Z-count in time format
    Option by default: the time is displayed in the MM:SS.t format (t = tenths of second).If this option is not set, the time is displayed as received, i.e. in multiple of 0.6 sec.This is the time elapsed since the previous round hour, at which the corrections arecomputed.

    FEC-A

    Protocol: transmission of 2 channels, bits interleaved. The characters of a messageare transmitted in one of the 2 channels and the bits of an error correcting cyclic codein the second one.
    Code: FEC-A, 7 bit words, 34 characters set. 32 characters are formed by: 1 bit(0), 5 bits of the Baudot code and 1 even parity bit for the detection of errors. 2supplementary characters are added (RQ and beta).
    Current speeds: 96, 144, 192 bauds
    Current modulation: FSK
    Main use: military and diplomatic traffic, news.
    RadioRaft particular: RadioRaft does not provide error correction.

    HNG-FEC

    Hng-fec characteristics

    Protocol: each bit of a character is spread on 64 bits and is interleaved with thebits of other characters.
    Code: 15 bit words for 5 effective data bits (redundancy for the errorcorrection), 32 characters set.
    Current speed: 100.05 Bauds.
    Current modulation: FSK
    Main use: diplomatic traffic.
    RadioRaft particular: if the shift is reversed, the decoding will be correctbecause a reversed code word is also a valid code word. On the other hand erroneouscharacters will be displayed. To alleviate this difficulty, RadioRaft attempts to find theright shift by understanding some transmitted characters. This needs time, and even failsif the transmitted message is encrypted or if it contains some particular sequences.

    Hng-fec options

    Auto-shift (enabled by default)
    To enable/disable the automatic detection of the shift (enabled by default).
    Reversed shift
    Clicking on 'Reversed shift' inhibits the automatic shift detection, and thenswitches to the normal or reversed shift.

    POCSAG

    Pocsag characteristics

    Protocol: transmission of lots of one synchronization word followed by 16 codewordscontaining addresses and numerical or alphanumerical data.
    Code: 32 bit words:
    Bits for data can contain numerics or alphanumerics, depending on the pager service.
    Current speeds: 512, 600, 1200 and 2400 Bauds.
    Modulation: DFSK at +/- 4.5 Khz.
    IMPORTANT:As in DFSK the data signal directly modulates the HF carrier, youwould need to connect directly the interface to the FM discriminator of your receiver,without capacitor. This permits to keep the continuous component of the data signal whenlong series of 0 or 1 are transmitted.
    Another simpler way is to use the classical interface connected to the speacker output buthaving a hysteresis adjustment. It allows to maintain the right level when the data signalis constant. In the Diagram of the interface shown in theRadioRaft user's manual, the resistances R2/R3 permit to adjust the hysteresis.
    You must adjust the signal level just above the threshold of hysteresis.
    If you are using an ordinary interface, you will not be able to receive POCSAGexcept if your receiver passes audio frequencies below 50 Hz which is a bit out ofordinary.
    RadioRaft particular: RadioRaft is able to correct 2 errors per word even in thesynchronization word.
    Main use: POCSAG is used on VHF and UHF for message transmissions topagers.

    Pocsag message display

    RadioRaft displays the address of the pager in octal, followed by the service number(0: numerics, 3: alphanumerics), then the message. Examples:
    6154773-0| 003312345678
    7610321-3| Midnight! It's time you go home. Mummy.

    Pocsag options

    Checksum (enabled by default)
    The display of messages is interrupted when a CRC error is encountered in a codewordand the error cannot be corrected.
    Error correction (enabled by default)
    RadioRaft corrects possible errors. RadioRaft can correct 2 erroneous bits by codewordeven for the synchronization word.
    End of message on {nul} (enabled by default)
    The reception is stopped if an ASCII character NUL is encountered.
    All messages (enabled by default)
    The options 'All messages', 'Alphanumerics', 'Text only'and 'Numerics' are mutually exclusive.
    If 'All messages' is active, RadioRaft displays all messages (numerics oralphanumerics).
    Alphanumerics
    RadioRaft displays only alphanumerical messages.
    Text only
    RadioRaft displays only alphanumerical messages that contain at least one letter.
    The option permits to cancel pure numerical messages that are transmitted toalphanumerical pagers.
    Numerics
    RadioRaft displays only numerical messages.
    Disable empty messages
    RadioRaft doesn't display messages without data.

    Decode Pocsag

    RUM-FEC

    Rum-fec characteristics

    Protocol: each bit of a character is spread on 129 bits and is interleaved with thebits of other characters.
    Code: 16 bit words for 5 effective data bits (redundancy for the errorcorrection), 34 characters set.
    Current speeds: 164.5 and 218.3 Bauds.
    Current modulation: FSK
    Main use: diplomatic traffic.
    RadioRaft particular: if the shift is reversed, the decoding will be correctbecause a reversed code word is also a valid code word. On the other hand erroneouscharacters will be displayed. To alleviate this difficulty, RadioRaft attempts to find theright shift by understanding some transmitted characters. This needs time, and even failsif the transmitted message is encrypted, or if it contains some particular sequences.
    Due to the wide spread, the scanning needs at least 16 seconds of signal beforeRadioRaft synchronizes.

    Rum-fec options

    Auto-shift (enabled by default)
    To enable/disable the automatic detection of the shift.
    Reversed shift
    Clicking on 'Reversed shift' inhibits the automatic shift detection, and thenswitches to the normal or reversed shift.

    SITOR-B, NAVTEX

    The SITOR mode B is also known by radioamateurs as AMTOR mode B or TOR/FEC.

    Sitor-B characteristics

    Protocol: CCIR Recommendation 476-4. Transmission of 2 channels, charactersinterleaved. One channel transmits the same message as the second one but with a delay of4 characters.
    Error correction: if a character in the first channel is erroneous, it is taken from thesecond channel.
    Code: CCIR 476-4, 7 bit words, 4 of which are always set to 1 for the detectionof errors if this criterion is not verified.
    Current speed: 100 bauds
    Current modulation: FSK
    Main use: weather reports, warnings to navigators and call lists for ships,radioamateurs.

    NAVTEX

    NAVTEX is not a mode but a particular SITOR-B transmission of messages for the urgentwarnings to navigators, on 518 kHz.
    The headers of such messages are formatted and the rest as plain text.
    RadioRaft displays the headers as they are (no decoding of the numerical fields) and themessage body as plain text.

    SPREAD

    Protocol: each character is spread on 11, 21 or 51 bits, each bit of a character isinterleaved with the bits of other characters.
    Code: Bauer code, 10 bit words (5 bits like ITA2 and 5 bits for the errorcorrection by a Hamming code), 32 characters set.
    Standard speeds: 62.3, 68.5, 102.6, 137 and 218.3 Bauds.
    Current modulation: FSK
    Main use: formerly diplomatic trafic
    RadioRaft particular: the modes are named SPREADx where x=11, 21 or 51 dependingon the spread.

    1382

    1382 characteristics

    Protocol: transmission of a bit pattern for the bit phasing, then a 32 bitsynchronisation word followed by the codewords
    Decoder
    Code: 64 bit words containing 48 data bits and 12 bits for the error detectionby a cyclic code.
    The 48 data bits may also include a convolutional code for the error correction (notimplemented in RadioRaft and not used by the pagers).
    Standard speed: 1200 Bauds.
    Current modulation: MSK 1200/1800 Hz. Warning: this modulation is verysensitive to noise or interferences.
    Main use: used in France to transmit messages to pagers in emergency services(similar to Pocsag). 1382 is also used to pass signalling in private radiotelephonenetworks.
    RadioRaft particular: 1382 is the reference of the protocol. RadioRaft decodesonly the version of 1382 used in emergency services, particularly by firemen.

    1382 Options

    Start on {Stx}
    Option by default : no text is displayed until ASCII code 02 (STX) is received.
    Stop on {Etx}
    Option by default : text is not displayed after receiving ASCII code 03 (ETX).
    Stop on error
    RadioRaft stops the display after an error is encountered. This option is disabled bydefault.

    PACKET MODES

    These modes don't need that transmitting and receiving stations aresynchronized. A packet can be sent at any time.

    ACARS-VHF

    Acars-vhf characteristics

    Protocol: Refer to ARINC characteristic 597-4. Packets contain:
    Code: ASCII 7 bits + 1 even parity bit.
    Current speed: 2400 bauds
    Modulation on VHF: FFSK 1200/2400 Hz. The presence of 1200 Hz indicates abit change from the previous value, the presence of 2400 Hz indicates that there is no bitchange.
    Particular: you need a receiver with a good audio quality to decode ACARSmessages, specially flat frequency and phase response.
    On HF the modulation is very different. RadioRaft doesn't demodulate ACARS HFmodulation. It doesn't decode ACARS-HF.
    Use: earth/planes aeronautical information exchange.

    Acars-vhf messages display

    RadioRaft doesn't decode data fields of the Acars protocol. It displays the field namesfollowed by their contents as they are.
    For example:
    ----Mode:J---Address:.F-ABCD---ACK:{NAK}---Label:Q3---Mode:A---Block:3
    Text: Please book 2 seats tonight at Moulin Rouge. Landing Paris soon.
    See above the ACARS protocol for the meaning of the fields. Text is displayed as plaintext but it can appear unclear when it is formatted for technical information exchange.

    Acars-vhf option

    Checksum (enabled by default): the checksum control of the whole frame is active.When disabled, frame including errors are nevertheless displayed as well as characterswith parity error.
    In normal functioning, 'Cheksum' must be enabled.

    GMDSS-DSC

    Gmdss-dsc characteristics

    Protocol: ITU-R M.493. Characters are transmitted by packets with an error-checkcharacter for the entire sequence. Each character is transmitted twice in a time-spreadmode. The repetition of a character occurs 4 character after its first transmission, as inSITOR-B.
    Code: 10 bits words allowing error detection, 128 characters set. Symbols 0 to 99 are used to transmit numerical values. The meaning of characters 100 to127 depend on their position in the message and on the message format.
    Current speeds: 100 bauds (hectometric and shortwaves), 1200 bauds (VHF).
    Current modulation: FSK. HF: shift is 170 Hz. VHF: shift is 800 Hz(Mark/space: 1300/2100 Hz).
    Main use: DSC is the selective calling mode of the Global Maritime Distress and Safety System.
    IMPORTANT RadioRaft particular: RadioRaft decode all DSC messages except: distressrelay, distress relay acknowledgement and selective call to a group of ships ina particular geographic area. It decodes distress calls.

    Gmdss-dsc messages display

    Examples:
    SelCall>Address: 123-456789 Category:Safety
    Self-Id
    : 987-654321
    Message: F3E/G3E simplex telephone {RQ}
    SelCall>Address: 123-456789 Category:Routine
    Self-Id
    : 987-654321
    Message: None
    Rx frequency
    : 16419.5 Tx frequency:16419.1 {BQ}
    <<<DISTRESS CALL>>>
    Self-Id: 123-456789
    Nature: Collision
    Coordinates (lat/long): NE 04°29' 033°15' Time: 12:47
    Message: J3E telephone
    Refer to recommendation ITU-R M.493 to interpret the different fields.
    In brief:
    The message begins with the format specifier of the message as plain text(SelCall, Distress call...)
    Address: 9 digits address of the ship or 10 digits address of a group of ships
    Category: category of the message (distress, urgency, safety, ship's business,routine)
    Self-Id: self-identification of the calling station. It is the maritime mobile serviceidentity (MMSI)
    Message: message as plain text (coordinates, frequencies or channels, type of communication...)
    {BQ} or {RQ}: RQ if the call requires acknoledgement, BQ if it is an answerto a call with RQ, nothing in other cases.
    Nature: nature of the distress, in distress messages only.
    Coordinates: position at the time of the distress call.
    Time: time of the distress call.
    RadioRaft adds {Checksum error} if the message contains at least an erroneouscharacter.

    PACKET (Packet radio)

    Packet characteristics

    Protocol: AX25 (X25 variant protocol). Packet frames contain:
    Code: none. Any data types can be placed in the data bytes. When text istransmitted, ASCII is used with the 8th bit at 0.
    Current speeds: 300 (shortwaves only), 1200, 2400, 9600 bauds
    Current modulation: FSK (except above 2400 bauds)

    Packet messages display

    For each PACKET frame, RadioRaft displays the call signs with the SSID of the stationof destination, of source and of possible repeaters, then the control byte and the PID inhexadecimal format. Finally the possible information text of the frame is displayed. Apacket appears as follows:
    A3XYZ -0<F6FLT -0EA8XYZ-103/15/ HI ELMER! WHAT'S UP DOC?
    (for ex. a message from F6FLT to A3XYZ via EA8XYZ, with the control byte = 03, and thePID = 15). Any information type can be transmitted in PACKET (pictures, computer programs,text or sound files...).
    The ASCII code is generally used for text transmissions. RadioRaft displays theinformation content of a PACKET frame with the 8-bit ASCII code. If you view frames ofinformation containing a program or a picture, codes of the file will be interpreted asASCII characters and displayed as cabalistic signs!

    Packet options

    Cheksum (enabled by default)
    The checksum control is active. If disabled, frames including errors are neverthelessdisplayed. In normal functioning, 'Cheksum' must be enabled.
    Whole packet (enabled by default)
    Options 'Whole packet', 'Data only', 'Address only' aremutually exclusive.
    In normal functioning, 'Whole packet' is enabled, and therefore all frame dataare displayed, with addresses.
    Data only
    Only call signs of destination, source and possible repeater stations with their SSIDwill be displayed. Information data of the frames are not displayed.
    Address only
    Only information data of the frames will be displayed. In association with the filter,this option allows to follow the traffic from or to a particular station.
    Destination filter, Source filter
    When you select 'Destination filter' and/or 'Source filter',displayed messages are only those of a particular source station to a particulardestination station, of which you specify the call signs (during this selection, RadioRaftpositions automatically the cursor at the beginning of the field for the text input).
    If the 2 filters are active at the same time, only messages having both destination andsource call signs as addresses will be displayed.

    Pocsag Pager

    Note - you must enter the call signs in upper case. If you indicate no call sign, nomore packets will be displayed because RadioRaft will be expecting call signs with 6spaces!
    In normal functioning 'Destination filter' and 'Source filter' aredisabled. At any time you can enable or disable the filtering while the call signs remain.

    OTHER MODES

    BaudMeter

    The BaudMeter measures the speed of synchronous modes up to 300 bauds within 0.5 baud.Speeds of asynchronous modes are generally not found, except those having 1 start bit, 5data bits and 1 or more stop bits as Baudot. For other asynchronous modes, use the'DIGIT' mode.
    The speed is in fact the 'modulation rate'. A small window appears anddisplays the last measurement when it is available.
    You can also use the 'DIGIT' mode to measure the modulation rate (see thismode).
    BaudMeter option:
    Synchronous mode (enabled by default): you must disable thisoption to measure speed of asynchronous transmission as Baudot. Only speed of asynchronousmodes with 1 start bit, 5 data bits and 1 or more stop bits can be measured.
    To measure any other asynchronous modes, see the option 'Synchronous' of theDIGIT mode.

    Pocsag Decoder software, free downloads

    CW

    This is the well-known Morse code.
    WARNING: If you are using a MODEM, check that the 'shift' specified in the'Options' menu is right. The polarity indicator must indicate 1 when the signalis present, 0 when there is no signal.
    With the interface, the shift must be normal (not marked).
    Protocol: none.
    Code: Morse (invented by Samuel Morse)
    Speed: any. RadioRaft adapts itself automatically to the transmission speed. Thespeed is displayed in Bauds.
    You can fix the speed by disabling the 'scan-baud' or by entering a value inthe baud input field (menu 'Bauds').
    Usually, the CW speed is in Wpm, words per minute, but this is imprecise. The Morsereference element is the duration of a dot. The 'CW Baud' is therefore theopposite of this duration. For ex: 20 Bauds correspond to a dot duration of 1/20=50 ms(approximately 22 Wpm).
    Modulation: AM, sometimes FSK.
    RadioRaft perfectly decodes automatic transmissions in this mode, and 'does whatit can' for manual transmissions by operator: most operators have indeed a veryconsistent send rate, with the main default to paste letters together. In these conditionsonly a trained human brain can distinguish the meaning of --.--.... between:
    QTH (--.- - ....) or QNS (--.- -. ...) or GT6 (--. - -....) or ...

    DIGIT

    Digit characteristics

    This mode is unique to RadioRaft. It allows you to view a transmission bit-by-bit, in abinary or hexadecimal format, and to measure its speed. The bits are grouped in words tofacilitate viewing. When you start the program, the display is initialized for 7 bitswords, and 8 words rows (see the options about this subject).
    There is no correlation between these words and any character codes that would bereceived: for example in the case of the reception of a CCIR-476 code, the 7 bits of acharacter can be in between 2 words. 'DIGIT' ignores the nature of thetransmission. Keys F9/F10 allow to shift left or right the bits display.
    'DIGIT' is essentially a tool for analysis, to show exactly what is received.This tool can also be used to decode unknown modes. It requires the knowledge of thetransmission speed. DIGIT automatically seeks the valid speed.
    Digit does not display anything as long as it has not found the speed. If the scanningof the speed fails, you have to select it manually in the 'Bauds' menu. Thatforces the display of the received bits.
    For the asynchronous modes, see below the option 'Synchronous mode'.

    Digit options

    Words size
    This option sets the number of bits by word (1 to 252). The display in hexadecimalformat does not allow for exceeding 16-bit words. Above 16-bit words, only the last 16bits are processed. Click on the digits in the word size field: a left click increases thevalue, a right click decreases it. You can also press + or -.
    Words by rows
    This option sets the number of words in a row (1 to 32).
    Code...
    This command opens a menu for choosing the translation code you can use to display thecharacter corresponding to the last x bits (x is the number of bits by character of thecode. If x is minus than the size of words, only the last x bits of words are taken forthe translation.
    For ex. RY transmitted in Baudot:
    1001010 R|1010101 Y|1001010 R|1010101 Y...
    For each word, the first bit 1 is a stop bit of the previous character. The following 0is the start bit of the character. The next 5 bits (01010 or 10101) are the baudot code ofthe character, used for the translation.
    The menu 'Code...' permits also to:
    Invert H/L bits in words
    It inverts the bits of high and low order before the translation.
    Reverse 0/1 on error
    It allows you to reverse all the bits and resume the translation, after a firsttranslation fails with an erroneous character (e.g. ratio 4/7 unchecked in CCIR-342 or476, or word not found in the code set). This allows you to display modes that usecharacters reversals (ARQ-M, ARQ-E).
    Acars type
    With FSK or FFSK modulation, a bit at 0 corresponds to the lower frequency, a bit at 1to the higher.
    If you activate this option, the low frequency indicates a bit change from the previousbit, the high frequency indicates that there is no change.
    Synchronous mode
    You must disable this option (enabled by default) to view bit-by-bit an asynchronoustransmission or to measure its speed.
    In this case the knowledge of the number of bits by character is necessary: you mustset it in the option 'Words size'. If you want to view a Baudot transmission forexample, set 'Words size' to 7 (=1 start bit + 5 bits of the Baudot code + 1stop bit). The speed of the transmission cannot be found if the word size is not properlyset.
    Stop on missing signal
    The bits display will be stopped if no data signal transition is encountered within thetime fixed in the menu 'Options/Strategy/Time' (4 sec by default).
    Delta

    Pdw Software Pocsag

    'Delta' allows you to display the transitions from the input signal insteadof the state of bits (an absence of transition corresponds to 0, a transition to 1). Forexample enable this option to view a frame of an AX25 packet.
    Parity
    'Parity' allows you to display the parity of the last n received bits, nbeing the number of bits by word.
    Reverse 0/1
    Reverses the display 0/1 in 1/0.
    Even / Odd bits
    To enable 'odd or even bit' forces the display of only one by two bit of oddor even rank, which allows you to view one channel of a transmission with interleavedbits, like the ARQ-M4 or FEC-A modes.
    Binary / Hexadecimal
    The display is in binary or hexadecimal format. The hexadecimal is limited to 16-bitwords.

    LIST OF SOME FREQUENCIES

    For more informations about utility radio stations (list of frequencies, transmissionmodes...), please refer to the following guides and publishers
    - Guide to utility radio stations
    - Shortwave frequency guide
    by Joerg Klingenfuss
    Klingenfuss Publications
    Hagenloher Str. 14
    D-72070 Tuebingen
    Germany
    Phone ++49 7071 62830
    Fax ++49 7071 600849
    WEB http://ourworld.compuserve.com/homepages/Klingenfuss
    - Ferrell's Confidential Frequency list
    by Geoff Halligey
    PW Publishing Ltd
    Arrowsmith Court
    Broadstone
    DORSET BH18 8PW
    United Kingdom
    Phone (01202) 659910

    Back to the summary

    Back to the summary